Installation/Owner’s Manual
Series 6500
Series 6500
Series 6500
Copyright 2009 DoorKing, Inc. All rights reserved.
Copyright 2014 DoorKing, Inc. All rights reserved.
Date Installed:
Installer/Company Name:
Phone Number:
Leave Manual with Owner
Vehicular Swing Gate Operator
UL 325 Compliant
Circuit Board
Serial Number
and Revision Letter:
Use this manual for circuit board 4405-010 Revision E or higher.
6500-065-W-3-14
Zobrazit stránku 0
1 2 3 4 5 6 ... 47 48

Shrnutí obsahu

Strany 1 - Series 6500

Installation/Owner’s ManualSeries 6500Series 6500Series 6500Copyright 2009 DoorKing, Inc. All rights reserved.Copyright 2014 DoorKing, Inc. All rights

Strany 2

6500-065-W-3-148Swing Gate Requirements The operator is intended for installation only on gates used for vehicles. Pedestrians must be supplied with

Strany 3 - SPECIFICATIONS

6500-065-W-3-149Swing Gate Protection Non-contact SensorReverse Loop Shadow Loop Automatic Exit Loop C D D C Minimizes the potential of the gate clos

Strany 4 - TABLE OF CONTENTS

6500-065-W-3-1410SECTION 1 - INSTALLATION 1.1 Underground Conduit Requirements1.2 Concrete PadSweepsConcrete Pad Primary Operator Position Secondary

Strany 5

6500-065-W-3-1411 22” 28” 22” 28” Space Gained from Alternate InstallationStandard InstallationOperator Installation1.3 Type of Installations Reco

Strany 6

6500-065-W-3-1412 22” 28” 22” 28” Concrete Pad LocationOperator Installation 42” 23” 2” 90° Plus Installation requires the Standard Compact Insta

Strany 7 - Important Notices

6500-065-W-3-1413Gate Bracket Crank Arm Control Arm Release hub with release tool. DO NOT REMOVE HUB!Bolt crank arm to operator.Slide elbow assembly

Strany 8 - UL 325 Entrapment Protection

6500-065-W-3-14141.6 Determining Arm Lengths Slide elbow assembly back and fourth, manually opening and closing gate until satisfied with the gate’s

Strany 9 - Glossary

6500-065-W-3-14152.1 High Voltage Wire RunThe distance shown in the chart is measured in Feet from the operator to the power source. If power wiring

Strany 10 - Swing Gate Requirements

6500-065-W-3-14162.3 Bi-Parting Gates Wiring - Dual Gate Operators1Motor2Motor3Neutral424VAC5Limit6Spare7Limit8COM1Motor2Motor3Neutral424VAC5Limit6Sp

Strany 11 - Swing Gate Protection

6500-065-W-3-141720191817161514131211109876543211ON SW 12 3 4 1ON SW 2REVERSELOOPP2 P8EXITLOOPSELFTESTNCTIMEDELAYNOREV SENSEPRIMARYREV SENSESECONDARY

Strany 13 - Alternate Installation

6500-065-W-3-14183.2 DIP-Switch Settings for 4405 Circuit Board The two DIP-switches located on the circuit board are used to program the operator to

Strany 14 - Compact Installation

6500-065-W-3-14193.2 ContinuedSwitch 1 Must OPEN the primary operator’s gate upon initial AC power up and open command. If the FIRST open command beg

Strany 15 - CAUTION

6500-065-W-3-14203.3 Limit SensorsLoosen set screw to adjust the limit sensor.Magnetic OpenLimit SensorMagnetic CloseLimit SensorMagnetic Sensor Acti

Strany 16 - 1.6 Determining Arm Lengths

6500-065-W-3-1421LEDTest the operator reversing sensitivity:Dual Operators:12Place an immobile object along the gate path, allowing the gate to strik

Strany 17 - 2.1 High Voltage Wire Run

6500-065-W-3-1422AC PowerReverseShadowReversePrimaryOperatorSecondaryOperatorPrimary/secondary interconnection cablein underground conduit.PUSH TO OP

Strany 18 - Interconnection Cable Wiring

6500-065-W-3-142320191817161514131211109876543211ON SW 12 3 4 1ON SW 2REVERSELOOPP2 P8EXITLOOPSELFTESTNCTIMEDELAYNOREV SENSEPRIMARYREV SENSESECONDARY

Strany 19 - SECTION 3 - ADJUSTMENTS

6500-065-W-3-1424Non-Secure Side Outside PropertySecure Side Inside Property4.2 Entrapment and Safety Protection Device LocationsPhoto Sensors Sample

Strany 20 - SW 2 (Bottom 4 Switches)

6500-065-W-3-1425Automatic exit loop lead in wires are twisted approx. 6 twists per foot.Reverse loop lead in wires are twisted approx. 6 twists per

Strany 21 - 3.2 Continued

6500-065-W-3-14264405DANGERHIGH VOLTAGE!2019181716151413121110987654321SELFTESTNC NO12345678913121110141516171819205.1 Terminal DescriptionsSECTION 5

Strany 22 - 3.3 Limit Sensors

6500-065-W-3-1427Important: Controls must be installed a minimum of 10-feet from the gate or installed in such a way that the person using the contro

Strany 23 - Dual Operators:

6500-065-W-3-141Class of Operation Model 6500 - UL325 Class I, II, III, IV Type of Gate Vehicular Swing Gates Only Entrapment Protection Primary

Strany 24 - (Dual Gates ONLY)

6500-065-W-3-1428SECTION 6 - OPERATING INSTRUCTIONSWARNING - To reduce the risk of injury or death: 1. READ AND FOLLOW ALL INSTRUCTIONS. 2.

Strany 25 - Closing Gate

6500-065-W-3-14296.2 Shutdown ConditionsUnder various entrapment conditions the operator will assume either a soft or hard (alarm) shutdown. To deter

Strany 26 - Photo Sensors Sample Setup

6500-065-W-3-14306.3 Manual Gate OperationThis operator is equipped with a manual release system that will allow the gate to be pushed open in the ev

Strany 27 - 4.3 Loop Detector Wiring

6500-065-W-3-1431Manual Release Remove release tool and place where shown. Release hub. Gate can now be manually operated. B C Unlock the cover and

Strany 28 - 5.1 Terminal Descriptions

6500-065-W-3-1432SECTION 7 - OPTIONAL CONVENIENCE OPEN ADJUSTMENTSThe optional convenience open system installed in your vehicular gate operator is d

Strany 29 - 5.2 Control Wiring

6500-065-W-3-1433DC Motor Negative OutputDC Motor Positive OutputBattery Negative InputBattery Positive Input24 VAC Common24 VAC InputActivation Outp

Strany 30 - 6.1 Power and Reset Switches

6500-065-W-3-14348.1 MaintenanceSECTION 8 - MAINTENANCE AND TROUBLESHOOTINGInspection and service of this gate operator by a qualified technician sho

Strany 31 - 6.2 Shutdown Conditions

6500-065-W-3-14358.2 TroubleshootingHave a good VOM meter to check voltages and continuity. A Meg-Ohm meter capable of checking up to 500 meg-ohms o

Strany 32 - 6.3 Manual Gate Operation

6500-065-W-3-1436• Check the reversing sensitivity.• Disconnect gate from the gate operator and check that the gate swings freely without any bindi

Strany 33

6500-065-W-3-14378.3 Built-in DiagnosticsThis gate operator is designed with built-in diagnostics that will alert you to potential or existing proble

Strany 34 - 7.1 Operating Mode

6500-065-W-3-142SPECIFICATIONS 1ASTM F2200 Standard for Gate ConstructionImportant Safety InstructionsInstructions regarding intended installation:Im

Strany 35 - 7.2 DC System Description

6500-065-W-3-14388.4 Accessory ItemsThe following accessory items are available for the model 6500 swing gate operator.Contact Sensors - For use as a

Strany 36 - 8.1 Maintenance

6500-065-W-3-14398.5 Gearbox Shaft Extension ReplacementCLOSEOPENGearbox Shaft Extension with 4 Keys P/N 6500-147KeyCrank ArmKeyKeyKeyGearbox P/N 260

Strany 37 - 8.2 Troubleshooting

6500-065-W-3-144020191817161514131211109876543211ON SW 12 3 4 1ON SW 2REVERSELOOPP2 P8EXITLOOPSELFTESTNCTIMEDELAYNOREV SENSEPRIMARYREV SENSESECONDARY

Strany 38 - Symptom Possible Solution(s)

6500-065-W-3-144120191817161514131211109876543211ON SW 12 3 4 1ON SW 2REVERSELOOPP2 P8EXITLOOPSELFTESTNCTIMEDELAYNOREV SENSEPRIMARYREV SENSESECONDARY

Strany 39 - 8.3 Built-in Diagnostics

6500-065-W-3-144220191817161514131211109876543211ON SW 12 3 4 1ON SW 2REVERSELOOPP2 P8EXITLOOPSELFTESTNCTIMEDELAYNOREV SENSEPRIMARYREV SENSESECONDARY

Strany 40 - 8.4 Accessory Items

6500-065-W-3-144320191817161514131211109876543211ON SW 12 3 4 1ON SW 2REVERSELOOPP2 P8EXITLOOPSELFTESTNCTIMEDELAYNOREV SENSEPRIMARYREV SENSESECONDARY

Strany 41 - 6500-065-W-3-14

6500-065-W-3-14442340 Model 6500 1/2 HP Secondary Operator Model 6500 1/2 HP Secondary Operator/Convenience Open ––++Magnetic Open Sensor 1/2 HP 50uf

Strany 42 - Model 6500 1/2 HP 115 VAC

6500-065-W-3-14452340 Model 6500 1 HP Secondary Operator Model 6500 1 HP Secondary Operator/Convenience Open ––++Magnetic Open Sensor 1 HP DC Power B

Strany 43 - Current Sensor

6500-065-W-3-1446Copyright 2009 DoorKing, Inc. All rights reserved.www.doorking.comDoorKing, Inc.120 Glasgow AvenueInglewood, California 90301U.S.A.P

Strany 44 - Model 6500 1 HP 115 VAC

6500-065-W-3-143SECTION 4 - ENTRAPMENT AND SAFETY PROTECTION 232324254.1 UL 325 Terminal Description4.2 Entrapment and Safety Protection Device Loc

Strany 45

6500-065-W-3-144Instructions regarding intended installation: Vehicular gates should be constructed and installed in accordance with ASTM F2200; Stan

Strany 46

6500-065-W-3-145• For gate operators utilizing contact sensors: 1. One or more contact sensors shall be located where the risk of entrapment or o

Strany 47

6500-065-W-3-146UL 325 Entrapment ProtectionClass I Class I and II Class III Class IV Class II Class III Class IV A vehicular gate operator (or syst

Strany 48

6500-065-W-3-147GlossaryGATE - A moving barrier such as a swinging, sliding, raising, lowering, or the like, barrier, that is a stand-alone passage b